Roboteq Dual Channel Digital Motor Controller AX2550 Uživatelský manuál Strana 135

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 186
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 134
AX1500 Motor Controller Users Manual 135
Accessing & Changing Configuration Parameter in Flash
These parameters are stored in the controllers Flash memory and are not intended to be
changed at runtime.
Important Notice
The above parameters are stored in the MCUs configuration flash. Their storage is perma-
nent even after the controller is powered off. However, because of the finite number of
times flash memories can be reprogrammed (approx. 1000 times), these parameters are
not meant to be changed regularly, or on-the-fly.
All parameters in Flash (except for the Amps calibration) are reset to their default
values every time new firmware is loaded into the controller.
Input Control Mode
Address: ^00
Access: Read/Write
Effective: After Reset
This parameter selects the method the controller uses for accepting commands
Motor Control Mode
Address: ^01
Access: Read/Write
Effective: After Reset or ^FF
^1C Joystick Max 2 MS Instant
^1D Joystick Max 2 LS Instant
^F0 Amps Calibration Parameter 1 Reset
^F1 Amps Calibration Parameter 2 Reset
Value Mode See pages
0 R/C Radio mode (default) page 101
1 RS232, no watchdog page 101
2 RS232, with watchdog
3 Analog mode page 113
TABLE 22. Configuration parameters in Flash
Location Description Active after
Zobrazit stránku 134
1 2 ... 130 131 132 133 134 135 136 137 138 139 140 ... 185 186

Komentáře k této Příručce

Žádné komentáře