Analog Control and Operation
94 AX500 Motor Controller Users Manual Version 1.9b. June 1, 2007
Connector I/O Pin Assignment (Analog Mode)
When used in the Analog mode, the pins on the controllers DB15 connector are mapped
as described in the table below
TABLE 14. DB15 Connector pin assignment in Analog mode
Pin
Number Signal
Input or
Output Description
1 Output C Output 2Amp Accessory Output C (same as pin 9)
2 Data Out Output RS232 data output to the PC for data logging
3 Data In Input unused
4 Input F Input See Special Use of Accessory Digital Inputs on
page 46
5 Ground Out Power Output Controller ground (-)
6
7
8 Input E Input
9 Output C Output 2Amp Accessory Output C (same as pin 1)
10 Channel 2 In Analog in Channel 2 analog input
11 Channel 1 In Analog in Channel 1 analog input
12 Output D Output
13 Ground Out Power Controller ground (-)
14 +5V Out Power Output +5V Power Output (100mA max.)
15 Switch Input Input Emergency Stop or Invert Switch input
Pin1
8
15
9